Low Pressure Non-Incendive Pressure Sensor - Class 1 Div 2 Groups A, B, C, D Non-Incendive

The AST43LP is a low pressure Class I Division 2 stainless steel pressure transmitter / pressure transducer for use in hazardous areas. In addition to its rugged construction and the best price-to-performance ratio in the industry, the AST43LP is the solution for low pressure measurement for a variety of applications. The AST43LP is also now available with CSA Single Seal Approval.

- UL/cUL 1604 Class 1 Division 2 Non-Incendive Groups A, B, C, D
- CSA 213 Class 1 Div 2 Non-Incendive Groups A, B, C, D with Single Seal
- High Strength Stainless Steel Construction with all 316L
- Wide Operating Temperature Range
- Ranges from 0-2.5 to 0-15 PSI
- Low Static and Thermal Errors
- Unparalleled Price and Performance
- Compatible with Wide Range of Liquids and Gases
- EMI/RFI Protection
- Industrial OEM Equipment
- Refrigeration
- Water Management
- Oil & Gas Platforms
- Pressure Instrumentation
- Process Control
- Gas Compression & Storage
- Test Stands
- Vapor Recovery
- External Tank Level
Click Here For Wiring Information
1 Accuracy includes: Non-linearity, Hysteresis and Non-repeatability
AST43LP |
A |
00005 |
P |
4 |
L |
0 |
000 |
SS |
|
||||||||||||||||
| Series Type | |||||||||||||||||||||||||
| Process Connection A= 1/4" NPT Male F= 7/16"-20 UNF Male I= 1/4" NPT Female |
|||||||||||||||||||||||||
| Pressure Range Insert 5-digit pressure range code |
|||||||||||||||||||||||||
Pressure Unit
|
|||||||||||||||||||||||||
Outputs
|
|||||||||||||||||||||||||
|
Electrical I= DIN 43650A L= Conduit fitting, Cable 2 ft. (0.6m) M= Conduit fitting, Cable 4 ft. (1.2m) N= Conduit fitting, Cable 6 ft. (1.8m) P= Conduit fitting, Cable 10 ft. (3.0m) |
|||||||||||||||||||||||||
| Wetted Material 1= 316L |
|||||||||||||||||||||||||
| Options 000= No Special Options |
|||||||||||||||||||||||||
| Single Seal | |||||||||||||||||||||||||
Workmanship - AST43LP low pressure non-incendive pressure transmitters have a limited one-year warranty to the original purchaser. AST, Inc. will replace or repair, free of charge, any defective pressure transmitter. This warranty does not apply to any units that have been modified; misused, neglected or installed where the application exceeds published ratings. AST43LP is not recommended for use with hydrogen. AST's sensors are made with pride in New Jersey, USA. If in the area please feel free to stop by for a visit!